C-1000/C-2000

Alarm ID

Alarm Text

Help Text

100

Close doors/ reset emergency stop

101

Thermal failure

Check motor and reset thermal

circuit breaker in control cabinet

102

Step by step is activated

103

Dry run is activated

104

Machine reset by operator

105

Air pressure not ok

Check compressed air supply

150 / 550

Load blank magazine

151 / 551

Blank magazine empty

Load blank magazine and press [I]

152

Remove blank at suction frame

Close door and/or reset emergency stop

Press [//] followed by [I]

153

Suction frame manually moved

Press [I] to initialize the machine

154

Check position impuls sensor suction frame

Period of time of high and low signal

must be equal for a proper detection

155

Watchdog suction frame activated

Check home position sensor

Check compressed air supply

156

Watchdog flapfolders activated

Check home position sensor

Check compressed air supply

157

Failure suction frame

Check minimum amount of blanks on magazine

Check handwheel 5 and photocell

Check vacuum

Clean venturi / suction cups

158 / 552

Magazine almost empty

Load magazine

159

Suction frame not stand-by

Remove case

Check home position sensor

160

Failure retract cylinder

Check home position sensor

Check compressed air supply

161

Drive failure suction frame

162

No connection drive suction frame

200

Failure case transport pusher bar

Remove case

Check setting handwheel 6

201

Remove case at suction frame

Close door and/or reset e-stop

Press [//] followed by [I]

202

Pusher bar manually moved

Press [I] to initialize the machine

203

Watchdog pusher bar activated

Check home position sensor

Check movement speed

204

Pusher bar not stand-by

Remove case

Check home position sensor

205

Drive failure pusher bar

206

No connection drive pusher bar

250

Remove case in side belts

Close door and/or reset e-stop

Press [//] followed by [I]

251

Failure case transport side belts

Remove case

Check setting handwheel 6

252

Discharge not free

Machine running, discharge blocked

253

Side belts not stand-by

254

Drive failure side belts

255

Drive failure side belts fixed side

256

Drive failure side belts adjustable side

257

No connection drive side belts

258

No connection drive side belts fixed side

259

No connection drive side belts adjustable side

300

Failure tape dispencer

Check tape dispenser

Check alignment tape check sensor

301

Tape dispenser almost empty

Replace tape

302

Tape check is off

350

Watchdog output glue gun

Check: Output configuration

351

Failure glue distance

Check: Case transport and glue distance

352

Hotmelt not at right temperature

Check settings glue unit

Check functioning glue unit

353

Glue unit almost empty

Refill glue unit

354

Glueing is off

400

Watchdog flap compressor activated

Check home position sensor

Check movement speed

401

Flap compressor not stand-by

Remove case

Check home position sensor

402

Compressor is off

403

Flapcompressor manually moved

Press [I] to initialize the machine

404

Drive failure flap compressor

Check drive for error code

405

Communication failure drive flapcompressor

Check drive connections

450

Simulation line communication active

Simulation can be deactivated in engineering option menu.

451

Force line communication inputs active

Forcing communication inputs can be deactivated in engineering option menu.

452

Force line communication outputs active

Forcing communication outputs can be deactivated in engineering option menu.

453

No line communication

Alive pulse communication partner missing.

550

Load blank magazine

551

Blank magazine empty

552

Magazine almost empty

JavaScript errors detected

Please note, these errors can depend on your browser setup.